Air conditioners and heatpumps

ZU1 Series Heat Pumps
The ZU1 series air conditioners achieve a SEER of up to 25.0 in cooling mode and an HSPF of up to 13.0 in heating mode. The units are also ENERGY STAR® certified, the U.S. Environmental Protection Agency’s program for identifying energy-efficient products.
View flyer

AY-XP12ZU1 model: specifications

MODELS NUMBER
Indoor Unit
AY-XP12ZU1
AHRI: 213194987
MODELS NUMBER
Outdoor Unit
AE-X12ZU1
Performance
Cooling (Btu/h)
12 000

Min - Max (Btu/h)
2 800 - 13 600

Heating (Btu/h)
14 000

Min - Max (Btu/h)
3 200 - 17 100

Maximum heating @ -8,3 °C (17 °F)
 (Btu/h) (COP)
14 500 (2.44)

Maximum heating @ -15 °C (5 °F)
 (Btu/h) (COP)
12 000 (2.1)

Maximum heating @ -20 °C (-4 °F)
 (Btu/h) (COP)
10 100 (1.84)

Maximum heating @ -25 °C (-13 °F)
 (Btu/h) (COP)
8 200 (1.53)

Maximum heating @ -27 °C (-17 °F)
 (Btu/h) (COP)
7 200 (1.5)
EFFICIENCY
EER / EER 2
12.5 / 12.5

HSPF (IV) / HSPF 2 (IV)
12.5 / 11 - 9.6 / 9

SEER / SEER 2
21 / 22
POWER SUPPLY
V, Hz, Phase
208-230/60/1
MAXIMUM FUSE SIZE
(A)
15
DEHUMIDIFICATION
Pt/h
3.2
NOISE LEVEL (dB) COOLING
Indoor Unit (Sh/H/M/B/Sb)
42 / 39 / 34 / 27 / 23

Outdoor Unit
49
NOISE LEVEL (dB) HEATING
Indoor Unit (Sh/H/M/B/Sb)
43 / 40 / 35 / 28 / 23

Outdoor Unit
50
AIR FLOW (FT3/MIN)
Cooling (Sh/H/M/B/Sb)
438 / 385 / 307 / 219 / 145

Heating (Sh/H/M/B/Sb)
438 / 385 / 318 / 254 / 145
AIR FLOW DIRECTION
Horizontal
Auto

Vertical
Auto
OPERATING RANGE OF OUTSIDE
Cooling
14 à 115ºF (-10 to 46ºC)

Heating
-17 à 75°F (-27 to 24°C)
PIPE DIAMETER
Liq x Gas (inch.)
1/4 x 3/8
REFRIGERANT

R32
MAX PIPE LENGTH
{ft. (m)}
66 (20)

MAX HEIGHT DIFFERENCE
{ft. (m)}
33 (10)
DIMENSIONS (W X H X D)
Indoor Unit (inch.)
41-27/64 x 12-7/16 x 9-51/64

Outdoor Unit (inch.)
30-23/32 x 21-1/4 x 10-19/32
TOTAL WEIGHT
Indoor Unit {lbs. (kg)}
31 (14)

Outdoor Unit {lbs. (kg)}
67 (30)

AY-XP15ZU1 model: specifications

MODELS NUMBER
Indoor Unit
AY-XP15ZU1
AHRI: 213239134
MODELS NUMBER
Outdoor Unit
AE-X15ZU1
Performance
Cooling (Btu/h)
15 000

Min - Max (Btu/h)
5 000 - 17 000

Heating (Btu/h)
18 000

Min - Max (Btu/h)
4 500 - 21 800

Maximum heating @ -8,3 °C (17 °F)
 (Btu/h) (COP)
18 100 (2.21)

Maximum heating @ -15 °C (5 °F)
 (Btu/h) (COP)
15 300 (2.1)

Maximum heating @ -20 °C (-4 °F)
 (Btu/h) (COP)
13 200 (2.01)

Maximum heating @ -25 °C (-13 °F)
 (Btu/h) (COP)
11 100 (1.85)

Maximum heating @ -27 °C (-17 °F)
 (Btu/h) (COP)
10 100 (1.95)
EFFICIENCY
EER / EER 2
14 / 13.4

HSPF (IV) / HSPF 2 (IV)
11.8 / 11 - 9.5 / 8.7

SEER / SEER 2
24 / 24
POWER SUPPLY
V, Hz, Phase
208-230/60/1
MAXIMUM FUSE SIZE
(A)
20
DEHUMIDIFICATION
Pt/h
3.2
NOISE LEVEL (dB) COOLING
Indoor Unit (Sh/H/M/B/Sb)
46 / 42 / 38 / 30 / 26

Outdoor Unit
49
NOISE LEVEL (dB) HEATING
Indoor Unit (Sh/H/M/B/Sb)
46 / 42 / 36 / 30 / 23

Outdoor Unit
50
AIR FLOW (FT3/MIN)
Cooling (Sh/H/M/B/Sb)
636 / 558 / 441 / 328 / 251

Heating (Sh/H/M/B/Sb)
674 / 597 / 505 / 413 / 251
AIR FLOW DIRECTION
Horizontal
Auto

Vertical
Auto
OPERATING RANGE OF OUTSIDE
Cooling
14 à 115ºF (-10 to 46ºC)

Heating
-17 à 75°F (-27 to 24°C)
PIPE DIAMETER
Liq x Gas (inch.)
1/4 x 3/8
REFRIGERANT

R32
MAX PIPE LENGTH
{ft. (m)}
66 (20)

MAX HEIGHT DIFFERENCE
{ft. (m)}
33 (10)
DIMENSIONS (W X H X D)
Indoor Unit (inch.)
41-27/64 x 12-7/16 x 9-51/64

Outdoor Unit (inch.)
30-23/32 x 21-1/4 x 10-19/32
TOTAL WEIGHT
Indoor Unit {lbs. (kg)}
31 (14)

Outdoor Unit {lbs. (kg)}
67 (30)

AY-XP18ZU1 model: specifications

MODELS NUMBER
Indoor Unit
AY-XP18ZU1
AHRI: 213246053
MODELS NUMBER
Outdoor Unit
AE-X18ZU1
Performance
Cooling (Btu/h)
18 000

Min - Max (Btu/h)
6 000 - 21 600

Heating (Btu/h)
21 600

Min - Max (Btu/h)
5 500 - 25 600

Maximum heating @ -8,3 °C (17 °F)
 (Btu/h) (COP)
22 000 (2.3)

Maximum heating @ -15 °C (5 °F)
 (Btu/h) (COP)
18 000 (2.2)

Maximum heating @ -20 °C (-4 °F)
 (Btu/h) (COP)
15 000 (2.12)

Maximum heating @ -25 °C (-13 °F)
 (Btu/h) (COP)
12 000 (1.95)

Maximum heating @ -27 °C (-17 °F)
 (Btu/h) (COP)
11 500 (1.88)
EFFICIENCY
EER / EER 2
13 / 13

HSPF (IV) / HSPF 2 (IV)
13 / 11 - 10 / 9

SEER / SEER 2
24 / 24
POWER SUPPLY
V, Hz, Phase
208-230/60/1
MAXIMUM FUSE SIZE
(A)
25
DEHUMIDIFICATION
Pt/h
5.1
NOISE LEVEL (dB) COOLING
Indoor Unit (Sh/H/M/B/Sb)
45 / 43 / 40 / 31 / 28

Outdoor Unit
52
NOISE LEVEL (dB) HEATING
Indoor Unit (Sh/H/M/B/Sb)
49 / 47 / 41 / 31 / 25

Outdoor Unit
52
AIR FLOW (FT3/MIN)
Cooling (Sh/H/M/B/Sb)
636 / 597 / 480 / 328 / 251

Heating (Sh/H/M/B/Sb)
752 / 713 / 558 / 403 / 290
AIR FLOW DIRECTION
Horizontal
Auto

Vertical
Auto
OPERATING RANGE OF OUTSIDE
Cooling
14 à 115ºF (-10 to 46ºC)

Heating
-17 à 75°F (-27 to 24°C)
PIPE DIAMETER
Liq x Gas (inch.)
1/4 x 3/8
REFRIGERANT

R32
MAX PIPE LENGTH
{ft. (m)}
66 (20)

MAX HEIGHT DIFFERENCE
{ft. (m)}
33 (10)
DIMENSIONS (W X H X D)
Indoor Unit (inch.)
41-27/64 x 12-7/16 x 9-51/64

Outdoor Unit (inch.)
33-15/32 x 27 15/16 x 13
TOTAL WEIGHT
Indoor Unit {lbs. (kg)}
31 (14)

Outdoor Unit {lbs. (kg)}
95 (43)

AY-XP24ZU1 model: specifications

MODELS NUMBER
Indoor Unit
AY-XP24ZU1
AHRI: 213246054
MODELS NUMBER
Outdoor Unit
AE-X24ZU1u2000
Performance
Cooling (Btu/h)
22 000

Min - Max (Btu/h)
6 000 - 23 000

Heating (Btu/h)
24 000

Min - Max (Btu/h)
5 500 - 27 100

Maximum heating @ -8,3 °C (17 °F)
 (Btu/h) (COP)
22 400 (2.34)

Maximum heating @ -15 °C (5 °F)
 (Btu/h) (COP)
19 000 (2.2)

Maximum heating @ -20 °C (-4 °F)
 (Btu/h) (COP)
16 400 (2.08)

Maximum heating @ -25 °C (-13 °F)
 (Btu/h) (COP)
13 900 (1.91)

Maximum heating @ -27 °C (-17 °F)
 (Btu/h) (COP)
12 300 (1.92)
EFFICIENCY
EER / EER 2
10 / 10

HSPF (IV) / HSPF 2 (IV)
12.3 / 11 - 9.6 / 8.5

SEER / SEER 2
19 / 22
POWER SUPPLY
V, Hz, Phase
208-230/60/1
MAXIMUM FUSE SIZE
(A)
25
DEHUMIDIFICATION
Pt/h
6.8
NOISE LEVEL (dB) COOLING
Indoor Unit (Sh/H/M/B/Sb)
47 / 45 / 40 / 33 / 30

Outdoor Unit
53
NOISE LEVEL (dB) HEATING
Indoor Unit (Sh/H/M/B/Sb)
49 / 47 / 41 / 31 / 25

Outdoor Unit
54
AIR FLOW (FT3/MIN)
Cooling (Sh/H/M/B/Sb)
674 / 636 / 519 / 367 / 290

Heating (Sh/H/M/B/Sb)
752 / 713 / 558 / 403 / 290
AIR FLOW DIRECTION
Horizontal
Auto

Vertical
Auto
OPERATING RANGE OF OUTSIDE
Cooling
14 à 115ºF (-10 to 46ºC)

Heating
-17 à 75°F (-27 to 24°C)
PIPE DIAMETER
Liq x Gas (inch.)
1/4 x 3/8
REFRIGERANT

R32
MAX PIPE LENGTH
{ft. (m)}
66 (20)

DIFFu00c9RENCE MAX. DE HAUTEUR
{ft. (m)}
33 (10)
DIMENSIONS (W X H X D)
Indoor Unit (inch.)
41-27/64 x 12-7/16 x 9-51/64

Outdoor Unit (inch.)
33-15/32 x 27-15/16 x 13
TOTAL WEIGHT
Indoor Unit {lbs. (kg)}
31 (14)

Outdoor Unit {lbs. (kg)}
95 (43)